EPA UCMR 5 PFAS Monitoring Data

PFAS in Pennsylvania Drinking Water

Detection data from EPA UCMR 5 monitoring (20232025)

Last updated: May 28, 2026

Monitoring results are not compliance determinations. Detection levels reflect a specific sample point and date. Utilities may have taken corrective action after sampling. Methodology

Under the EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5), public water systems are required to test for 29 PFAS compounds between 2023 and 2025. This page summarizes the monitoring results reported for 354 water utilities in Pennsylvania, drawn directly from EPA's published occurrence data. 109 utilities reported one or more samples above an EPA Maximum Contaminant Level for PFOA, PFOS, PFNA, PFHxS, or HFPO-DA.

Highest PFOA / PFOS detections reported

UtilityAnalyteValue (ng/L)
Collegeville Trappe Joint Pwd
PA1460022
PFOA
235.00Above MCL
Emmaus Borough Public Water
PA3390032
PFOS
153.00Above MCL
Pa American Audubon
PA1460055
PFOS
57.90Above MCL
Caernarvon Twp Auth
PA3060052
PFOA
55.80Above MCL
Palmerton Municipal Authority
PA3130012
PFOA
42.50Above MCL
Palmerton Municipal Authority
PA3130012
PFOS
40.00Above MCL
Horsham Water&sewer Authority
PA1460033
PFOS
33.80Above MCL
Pa American Audubon
PA1460055
PFOA
30.80Above MCL
City of Lancaster
PA7360058
PFOA
23.80Above MCL
Northampton Bucks Co Mun Auth
PA1090089
PFOS
23.00Above MCL

Source: EPA UCMR 5 occurrence data. Detection levels reflect a single sample at a specific point in the system on the date shown. The EPA's Maximum Contaminant Level for PFOA and PFOS is 4 ng/L (finalized April 2024, compliance required by 2029). EPA UCMR 5

PFAS analytes — detection breakdown

PFPeA
599 / 2,143
PFBS
583 / 2,161
PFHxA
514 / 2,135
PFOAMCL 4 ppt
451 / 2,136
PFOSMCL 4 ppt
426 / 2,150
PFBA
238 / 2,096
PFHpA
195 / 2,095
PFHxSMCL 10 ppt
173 / 2,100

Detections / total records per analyte. All 29 UCMR 5 analytes shown where records exist for Pennsylvania.

All PA utilities with PFAS records

354 systems
Water System
Philadelphia Water Department
Philadelphia
Above MCL
View
Aqua Pa Main System
Above MCL
View
Pa Amer Water Co-pittsburgh
View
Pittsburgh Water & Sewer Auth
Pittsburgh
View
Erie City Water Authority
View
York Water Co
York
View
West View Water Authority
View
Mawc Sweeney Plant
View
Chester Water Authority
Above MCL
View
Pa Amer Water Co Lake Scranton
Scranton
Above MCL
View

How this data was collected

Source dataset

All records on this page are drawn from the EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) occurrence dataset, published by the U.S. Environmental Protection Agency. UCMR 5 required large public water systems (serving more than 3,300 people) to sample for 29 PFAS compounds between 2023 and 2025. EPA UCMR 5 occurrence data

Sampling methodology

Samples were collected at entry points to the distribution system (EPTDS) as required by UCMR 5 regulations. Each utility collected at least four quarterly samples during the monitoring period. Results represent concentrations at the specified sample point on the sample date — not a continuous measure of system-wide levels.

Unit normalization

Source data may express concentrations in micrograms per liter (µg/L, also written ug/L or ppb) or nanograms per liter (ng/L, also called ppt). All values on this page are normalized to ng/L (ppt) for consistent comparison with EPA Maximum Contaminant Levels (MCLs). Conversion: 1 µg/L = 1,000 ng/L. Records with unrecognized units are excluded from numeric aggregates and flagged in the raw export.

What "detection" means

A result is counted as a detection when the EPA reports it as "Detected above MRL" — meaning the analyte was measured at or above the minimum reporting limit (MRL) for that analyte. Non-detect results (below MRL) are included in total record counts but not in detection counts. Detection is a monitoring outcome, not a compliance determination.

Validation and exclusion criteria

Records are included only where validated = true and suppressed = false. Records flagged during ingestion for format errors, duplicate source hashes, or missing required fields are excluded.

Update cadence

Pages are regenerated every 24 hours via Next.js ISR. The underlying dataset is updated when EPA publishes new UCMR 5 occurrence data. The source retrieval date shown on each record reflects the date the EPA file was last downloaded to our system.

Cite this page

Water Utility Report. (2026). PFAS in Pennsylvania drinking water: EPA UCMR 5 monitoring records (2025). Retrieved May 28, 2026, from https://waterutilityreport.com/data/pfas/pennsylvania

Detection levels represent results from EPA-required compliance monitoring at the time of sampling. They are not a real-time indicator of current water quality. Utilities may have taken corrective action or installed treatment after sampling. For current information about your water, contact your utility or consult your annual Consumer Confidence Report.

At a Glance

Utilities tested

354

Total PFAS records

60,680

With detections

of 354

159

Above PFOA MCL (4 ng/L)

of 354

94

Above PFOS MCL (4 ng/L)

of 354

88

Above any individual MCL

PFOA, PFOS, PFNA, PFHxS, or HFPO-DA

109
Earliest sampleJanuary 10, 2023
Latest sampleDecember 1, 2025

Raw data

Download all 60,680 records for Pennsylvania as CSV.

Download CSV (60,680 records)